When a test is run on a resource in system verification mode, that resource has an entry in the AIX
error log. If the test on the resource was successful, the Resource Repair Action menu displays.
After replacing that FRU, you must select the resource for that FRU from the Resource Repair Action
menu. This updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Note: If the system attention indicator is on, this action will set it back to the normal state.
Perform the following steps:
1. From the RESOURCE REPAIR ACTION menu, select the parent
or child of the resource that has been replaced. If the repair action
was reseating a cable or adapter, select the resource associated
with that repair action. If the resource associated with your action
is not displayed on the resource list, select sysplanar0.
2. Press COMMIT after you make your selections.
3. If the No Trouble Found menu is displayed, continue with the
next step.
11. If you changed the service processor or network settings, as instructed in previous MAPs, restore the
settings to the value they had prior to servicing the system. If you ran stand-alone diagnostics from
CD-ROM, remove the stand-alone diagnostics CD-ROM from the system.
Did you perform service on a RAID subsystem that involvedchanging of the PCI RAID adapter
cache card or changing the configuration?
Note: This information does not apply to the PCI-X RAID adapter or cache.
No
Go to the close of call procedure.
Yes
Continue with the next step.
12. Use the Recover Options selection to resolve the RAID configuration. To do this, perform the
following steps:
1. On the PCI SCSI Disk Array Manager display, select Recovery
options.
2. If a previous configuration exists on the replacement adapter, this
must be cleared. Select Clear PCI SCSI Adapter Configuration
and press F3.
3. On the Recovery Options screen, select Resolve PCI SCSI RAID
Adapter Configuration.
4. On the Resolve PCI SCSI RAID Adapter Configuration screen,
select Accept Configuration on Drives.
5. On the PCI SCSI RAID Adapter selections menu, select the
adapter that you changed.
6. On the next screen, press Enter.
7. When you see the Are You Sure selection menu, press Enter to
continue.
8. If you see a Failed status message, verify that you selected the
correct adapter, and then repeat this procedure. When the
recovery is complete, exit the operating system.
9. Go to the Closing a service call procedure.