20. Add or update the FRU information:
Did you replace, add, or modify a FRU of the open service action event?
v Yes: Continue with the next step.
v No: Go to step 22.
21. Click OK to close the service action event.
22. Is the list of all partitions you recorded in step 11 on page 168 empty?
v Yes: Go to step 30 on page 170.
v No: Continue with the next step.
23. Does the list of all partitions you recorded in step 11 on page 168 contain more than one entry?
v Yes: Continue with the next step.
v No: Go to step 30 on page 170.
24. Is the error class recorded in step 23?
v Yes: Continue with the next step.
v No: Go to step 30 on page 170.
25. Perform all the following steps for each entry in the list of all partitions you recorded in step 11 on
page 168, except for the partition you were using to debug the original problem.
26. From the list of all partitions, open the IVM virtual terminal window of a partition, and then type
diag at the AIX command prompt.
27. When the diagnostic operating instructions are displayed, complete the following steps:
1. Press Enter.
2. Select the Task Selection option.
3. Select the Log Repair option.
4. Select the resource associated with the repair action:
v If the repair action was reseating a cable or adapter, select the resource associated with that repair action.
v If the resource associated with your repair action is not displayed on the Resource List, select sysplanar0.
5. Click Commit after you make your selection.
Note: If the terminal type is not defined, you are prompted to define it before you can proceed.
28. Exit from diagnostics in this partition and return to the AIX command prompt.
29. Have all the partitions in the list of all partitions you recorded in step 11 on page 168 been
processed?
Common service procedures
169