15. Add the partition list obtained in step 11 on page 159 to the existing list of Axx partitions obtained
from processing previous service action events in this maintenance analysis procedure (MAP).
16. Remove all entries in the list of all partitions you recorded in step 11 on page 159. If you are referred
to the list of partitions obtained in step 11 on page 159 in future steps, the list is empty. Go to step
17.
17. Select and highlight the service action event from the Error Associated With This Serviceable Event
window.
18. Click Close Event.
19. Add comments for the serviceable event. Include any unique additional information. Click OK. The
following steps will add or update FRU information.
20. Did you replace, add, or modify a FRU of the open service action event?
v Yes: Continue with the next step.
v No: Go to step 22.
21. From the FRU list, select a FRU that you need to update. Double-click the FRU, and update the FRU
information. Go to step 23.
22. Select the No FRU Replaced for this Serviceable Event option.
23. Click OK to close the service action event.
24. Is the list of all partitions you recorded in step 11 on page 159 empty?
v Yes: Go to step 32 on page 161.
v No: Continue with the next step.
25. Does the list of all partitions you recorded in step 11 on page 159 contain more than one entry?
v Yes: Continue with the next step.
v No: Go to step 32 on page 161.
26. Is the error class recorded in step 25 AIX?
160
Need help?