NAiS FP0 Series Hardware Manual page 79

Hide thumbs Also See for FP0 Series:
Table of Contents

Advertisement

FP0
4.2
Specifications
4.2.1
General Specifications
Item
Rated operation voltage
Operating voltage range
Rated current consumption
Allowed momentary power
off time
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Breakdown voltage
Insulation resistance
Vibration resistance
Shock resistance
Noise immunity
Operating condition
4.2.1.1
Weight
Type
A21
Matsushita Automation Controls
Description
24 V DC
21.6 to 26.4 V DC
100 mA or less (*section 2.2.1.2)
10 ms
0 C to +55 C/32 F to +131 F
- 20 C to +70 C/ - 4 F to +158 F
30% to 85% RH (non-condensing)
30% to 85% RH (non-condensing)
500 V AC for 1 minute between I/O terminal and power
supply/ground terminal
500 V AC for 1 minute between input and output terminals
min. 100 MΩ (measured with a 500 V DC megger) for
between I/O terminal and power supply/ground terminal
min. 100 MΩ (measured with a 500 V DC megger) for
between input and output terminals
10 Hz to 55 Hz, 1 cycle/min: double amplitude of 0.75 mm/
0.030 in., 10 min on 3 axes
2
Shock of 98 m/s
or more, 4 times on axes
1,000 Vp-p with pulse widths 50 ns and 1μs (based on
in-house measurements)
Free from corrosive gases and excessive dust
Weight
approx. 100 g/3.53 oz
Analog I/O Unit
4.2
Specifications
4 - 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents