NAiS FP0 Series Hardware Manual page 62

Hide thumbs Also See for FP0 Series:
Table of Contents

Advertisement

Expansion I/O Units
3.3
Internal Circuit Diagram
When the load voltage differs from the 24 V DC external power supply for the
driving the internal circuit
Other than 24 V DC load voltage, 5 V DC and 12 V DC and other load voltages can be
connected.
FP0-E8YT/E16YT
Internal circuit
Internal circuit
Internal circuit
. Note
The output number given above is the output number when the
expansion output unit is installed as the first expansion unit
(*section 5.3).
3 - 16
Output side
(+)
Y20
Load (for 5 V )
Y21
Load (for 5 V )
Y2n
Load (for 24 V DC)
(- )
5V DC
24 V DC
(Rated load
(External
voltage)
power supply
for driving
internal circuit)
Matsushita Automation Controls
FP0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents