Technical Specifications
5.3 Supported Networking Standards
5.3
Supported Networking Standards
5.4
Operating Environment
Ambient Operating
Temperature
Ambient Storage Tem-
perature
Ambient Relative Hu-
midity
Maximum Altitude
a
Measured from a 30 cm (11.8 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing.
5.5
Mechanical Specifications
Weight
Ingress Protection
Enclosure
5.6
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
38
Standard
10 Mbps
IEEE 802.1AB
Yes
IEEE 802.1D
Yes
IEEE 802.1Q
Yes
IEEE 802.1p
Yes
IEEE 802.1x
Yes
IEEE 802.3
Yes
IEEE 802.3u
No
IEEE 802.3z
No
IEEE 802.3ab
No
IEEE 802.3x
Yes
-40 to 85 °C (-40 to 185 °F)
a b
-40 to 85 °C (-40 to 185 °F)
5% to 95%
c
2000 m (6562 ft)
8.6 kg (19 lbs)
IP30
Aluminum
1000
100 Mbps
Mbps
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
Yes
Yes
Yes
Notes
Link Layer Discovery Protocol (LLDP)
MAC bridges
VLAN (Virtual LAN)
Priority levels
Port-based network access control
10Base-T
100Base-TX/100Base-FX
1000Base-SX/LX
1000Base-TX
Full duplex operation
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05
Need help?
Do you have a question about the SIMATIC NET RUGGEDCOM RSG2488F and is the answer not in the manual?
Questions and answers