Technical Specifications
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Power Sup-
24 VDC (Single)
48 VDC (Single)
High Volt-
age AC/DC
5.2
Failsafe Alarm Relay Specifications
NOTICE
The alarm switching voltage must be greater than the Safety Extra Low-Voltage
(SELV) to meet safety requirements.
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05
Terminal
ply Type
Block Type
Screw
Screw/
Pluggable
Parameter
Maximum Switching Voltage
Rated Switching Current
Maximum Switching Capacity
Input Range
Min
Max
13 VDC
36 VDC
38 VDC
72 VDC
98 VDC
300 VDC
88 VAC
264 VAC
Internal
Maximum
Fuse Rating
Power Con-
sumption
10 A
5 A
3.15 A
Value (Resistive Load)
250 VAC
30 VDC
2 A @ 250 VAC
2 A @ 30 VDC
150 W
500 VA
5
62 W
59 W
66 W
37