Error Codes And Flashing Sequences; 10.3.1 Flashing Sequences Of The Led - Homematic IP HmIP-FALMOT-C12 Installation Instructions And Operating Manual

Floor heating actuator - 12 channels, motorised
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting
10.3

Error codes and flashing sequences

10.3.1 Flashing sequences of the LED

Flashing code
Short orange
flashing
1x long green
lighting
1x long red
lighting
Short orange
flashing (every
10 s)
6x long red
flashing
66
Meaning
Radio transmis-
sion/
attempting to
transmit/data
transmission
Transmission
confirmed
Transmission
failed or duty
cycle limit is
reached
Teach-in mode
active
Device defective Please see your
Solution
Wait until the
transmission is
completed.
You can continue
operation.
Please try again
(see „10.1 Com-
mand not con-
firmed" on page
64 or „10.2 Duty
cycle" on page
65).
Please enter the
last four numbers
of the device
serial number to
confirm (see „6.4
Teaching-in" on
page 52).
app for
error message
or contact your
retailer.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading