Troubleshooting
7.3

Error codes and flashing sequences

Flashing
code
Short
orange
flashing
1x long green
lighting
Short
orange
flashing
(every 10
seconds)
1x long
red lighting
6x long red
flashing
38
Meaning
Radio transmis-
sion/attempting
to transmit/data
transmission
Operation
confirmed
Teach-in mode
active
Transmission
failed or duty
cycle limit is
reached
Device defec-
tive
Solution
Wait until the
transmission is
completed.
You can continue
operation.
Please enter the last
four numbers of the
device serial number
to confirm (see „5.3
Teaching-in" on
page 34).
Please try again (see
sec. „7.1 Command
not confirmed" on
page 36 or „7.2
Duty cycle" on page
37).
Please see your app
for error message or
contact your retailer.