Installation Manual
4.5.3
c-lever short plate variant
Kaba c-lever and variants
Requirement:
•
Outside shield installed
•
Centring sleeve positioned in outside shield
•
Mortise lock and lock cylinder installed
Procedure:
1.
Note: do not trap the antenna cable.
Place the support plate for the inside shield (40) over
the spindle (27) and lock cylinder (50) on the inside
of the door.
2.
Guide the antenna cable (13) through the cylinder
opening under the lock cylinder as shown.
3.
Note: tightening torque max. 2.5 ± 0.5 Nm.
Secure the support plate for the inside shield to the
outside shield using two fixing screws M5 (24).
4.
Unscrew the inside lever handle (17) with three
countersunk screws M4 (48) from the internal fitting.
k2evo702 - 201610
Installation
40
27
50
13
24
48
17
48
33