Installing Variant For Special Lever Handle Styles - Kaba c-lever 2662-K5 Installation Manual

Table of Contents

Advertisement

Installation
4.7.2

Installing variant for special lever handle styles

40
Procedure:
1. Note: do not trap the antenna cable.
Place the internal fitting (26), inside shield (19) and
lever handle on the spindle.
2. Align the internal fitting and push on to the lock cylin-
der.
3. Turn the inside shield 90° to the internal fitting.
4. Note: tightening torque max. 2.5 ± 0.5 Nm.
Secure the internal fitting and outside shield using
two fixing screws (24).
5. Place the inside shield parallel on the internal fitting.
-> Audibly clicks into place.
6. Secure the inside shield with a fixing screw M3 (25).
k2evo702 - 201610
Installation Manual
19
26
25
Kaba c-lever and variants