Installation
4.5.2

c-lever ES1 variant

32
Requirement:
Outside shield installed
Centring sleeve positioned in outside shield
Mortise lock and lock cylinder installed
Procedure:
1.
Note: do not trap the antenna cable.
Place the internal fitting (26) with the inside lever
handle on the spindle and lock cylinder.
2.
Screw in the top fixing screw (24) with a pull protec-
tion washer (35).
3.
Screw in the middle fixing screw (24).
4.
Screw in the bottom fixing screw (24) with a pull pro-
tection washer (36).
5.
Note: tightening torque max. 2.5 ± 0.5 Nm.
Secure the internal fitting and outside shield using
three fixing screws (24).
6.
Insert the antenna cable plug into the socket (59) of
the e-module for the internal fitting.
7.
Insert batteries if necessary.
8.
If batteries are already inserted, remove the contact
protection film.
9.
Slip the battery protection film [} 7.1] between the
batteries.