Table of Contents

Advertisement

Quick Links

Installation Instructions
CLAVIS Deutschland GmbH
Grüner Weg 38
34117 Kassel
Doc. No.: II_PAXOS_V001_20161007_EN
advance Series
Telefon:
E-Mail:
Internet:
0 7
1 3
0 8
0 )
1 0
1 3
1 0
3 0
: M
N 1
a d
: M
y p
o b
6 (E
/K e
K n
3 9
) w
ia l
S 2
/D
V d
2 (B
) w
s s
C la
3 (C
s s
S
C la
V d
0 7
1 3
0 8
1 0
1 3
0 )
: M
1 0
3 0
N 1
a d
: M
y p
o b
6 (E
/K e
K n
3 9
) w
ia l
S 2
/D
V d
2 (B
) w
s s
C la
3 (C
s s
S
C la
V d
0 7
1 3
8
1 0
3 0
0 )
0 1
: M
3 0
M 1
N 1
a d
y p
b :
n o
6 (E
/K e
l K
3 9
) w
S 2
/D ia
2 (B
V d
) w
s s
3 (C
C la
s s
S
C la
V d
+49 (0)561 988 499-0
info@tresore.eu
www.tresore.eu
www.tresorschloss.de
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAXOS advance Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kaba PAXOS advance Series

  • Page 1 6 (E /K e ia l 2 (B C la 3 (C C la 6 (E /K e ia l 2 (B C la 3 (C C la 6 (E /K e /D ia 2 (B 3 (C C la C la advance Series Installation Instructions...
  • Page 2 Tel. +41 848 85 86 87 www.kaba.com This documentation may not be reproduced in any way or otherwise used without the written consent of Kaba AG. Kaba® and PAXOS® advance are registered trademarks of Kaba AG. Copyright by Kaba AG 2015...
  • Page 3: Table Of Contents

    Installation Instructions Table of Contents Table of Contents About this Operating Manual Introduction Validity/limitation Target group Limitations Additional documentation Information and warning symbols 1.6.1 Danger to personnel 1.6.2 Danger to property 1.6.3 Other notes Marks and definitions in the text Safety and Environment Intended use General...
  • Page 4 Installation Instructions Operating Manual Installation Important information prior to installation Unpacking and checking the scope of supply Mounting the input unit Mounting the locks Mounting the door bolt/door position contacts Mounting the inner compartment locks Mounting the optional I/O-Box Installation and commissioning of the optional cover “VdS blocking element” for the I/O-Box 35 4.8.1 Required components 4.8.2...
  • Page 5: About This Operating Manual

    Installation Instructions About this Operating Manual About this Operating Manual Introduction The fully redundant electronic high-security locking system PAXOS advance IP (Paxos advance for short) is designed in accordance with the latest technology and meets all known safety standards. Nevertheless, improper operation of the electronic high-security locking system Paxos advance can lead to material damage or physical injury.
  • Page 6: Information And Warning Symbols

    About this Operating Manual Installation Instructions Information and warning symbols 1.6.1 Danger to personnel Risk of explosion! Indicates a potentially dangerous situation that in case of non-compliance may lead to minor injuries. 1.6.2 Danger to property CAUTION Indicates a potentially dangerous situation which, if not heeded, might lead to system damage or have a significant impact on the function and/or usage of the system.
  • Page 7: Safety And Environment

    Installation Instructions Safety and Environment Safety and Environment Intended use The locking system Paxos advance is used for locking and releasing the mechanical locking points of safe doors and inner compartment locks, which are generally operated manually via a bolt- work. The release (open locks) is only executed after entering one or more of the opening codes on the input unit.
  • Page 8: Disposal

    At the end of the service life or in case of replacement, the system components must be returned to Kaba AG or taken to a disposal or recycling point, in accordance with the locally applicable regulations. Under no circumstances may system components be disposed of in the environment.
  • Page 9: Product Description

    Installation Instructions Product Description Product Description System overview 3.1.1 Circuit diagram of the system setup Input unit 1 (required) Door lock 1 (required) Door bolt contacts (redundant, required) ENTER Door locks 2...n (optional) Batteries/rechargeable battery pack Inner compartment locks (optional) Input unit 2 (optional) Door bolt contacts (redundant, required for each inner...
  • Page 10: Application Example

    Product Description Installation Instructions 3.1.2 Application example 1 Input unit 2 Door lock 1 3 Door lock 2 4 Door bolt contacts 5 I/O-Box (optional) 6 IP-Box (optional) 7 Inner compartment locks Application example II_PAXOS_V001_20161007_EN PAXOS advance IP...
  • Page 11: System Description

    Installation Instructions Product Description 3.1.3 System description System setup – Minimum configuration The minimum configuration of the locking system Paxos advance comprises: – One input unit (with keypad or dial knob) – One door lock – Two door bolt contacts (to be provided by the customer) –...
  • Page 12 Product Description Installation Instructions IP-Box (optional) The optional IP-Box connects the Paxos advance locking system to an IP network. The IP-Box will be connected to the Paxos advance locking system’s redundant bus system over the bus connector and to the IP network over the RJ45 interface. To integrate the Paxos advance locking system into the network and to configure it, the optional AS384-NETW Management-Suite Software is required.
  • Page 13: Scope Of Supply

    Installation Instructions Product Description Scope of supply Sets and components The components of the locking system Paxos advance are supplied in sets and include the following content: Designation Contents Set 1 Class 2 (VdS 2396) or Class B (EN 1300) locking system, comprising: –...
  • Page 14: Paxos Advance Accessories

    Product Description Installation Instructions Designation Contents AS384-NETW, -USBW Optional programming software for configuring the locking system or -AUDITW and for viewing the audit either via USB or network, comprising: – CD (software, manuals) – SW dongle(s) – USB cable Order numbers: 82752Z0012 PAXAD-AS384-NETW 82753Z0004...
  • Page 15: Technical Data

    Installation Instructions Product Description Technical data 3.6.1 Input unit with keypad Dimensions (HxWxD) 137x135x60 mm Weight (without batteries/rechargeable batteries and mounting 410 g bracket) Material ABS injection moulded Fastening With mounting bracket and 2 M6 screws Electrical connection to the locking system Redundant bus cables (Bus a and Bus B) Display LCD with backlight, graphic 122 x 32 pixels (2 lines)
  • Page 16: Input Unit With Dial Knob

    Product Description Installation Instructions 3.6.2 Input unit with dial knob Dimensions (HxWxD) 137x135x60 mm Weight (without batteries/rechargeable batteries and mounting 405 g bracket) Material ABS injection moulded Fastening With mounting bracket Electrical connection to the locking system Redundant bus cables (Bus a and Bus B) Display LCD with backlight, graphic 122 x 32 pixels (2 lines) Viewing angle limitation...
  • Page 17: Lock

    Installation Instructions Product Description 3.6.3 Lock Dimensions (HxWxD) 85.0 x 60.4 x 30.9 mm Weight 440 g Material Zamak die-cast zinc Fastening 3 screws M6 Electrical connection to the locking system Redundant bus cables (Bus a and Bus B) Fastening carrier adapter to boltwork 1 screw M5 or 2 screws M4 Boltwork Adjustable 8.7, 12, 14 or 15 mm...
  • Page 18: I/O-Box

    Product Description Installation Instructions 3.6.4 I/O-Box Dimensions (HxWxD) 117 x 80,0 x 33,5 mm Weight 186 g Material housing Aluminium Fastening 4 screws M5 Electrical connection to locking system Redundant bus cables (Bus a and Bus B) Terminals for wire cross sections up to 1 mm Inputs Outputs Interface...
  • Page 19: Compliance/Standards And Regulations

    Installation Instructions Product Description Compliance/standards and regulations The Declaration of Conformity is supplied in a separate document. The fully redundant electronic high-security locking system Paxos advance complies with the standards and regulations in accordance with the information provided in the Technical Data (see section 3.6 “Technical data”).
  • Page 20: Installation

    Unpacking and checking the scope of supply Unpack the delivery and check the content is complete (based on the delivery slip) and check for any damage. Inform the transport company and the business partner immediately of any damage and any incomplete deliveries. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 21: Mounting The Input Unit

    The input unit is mounted at a convenient location for operation on the outside of the safe and is connected with the locks inside the safe by means of two bus cables. Dimensional diagram of the input unit (dimensions in mm) ENTER Dimensional diagram of the input unit PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 22 7.5 x 13 mm or a drill hole of ø 11 mm. Outline of the input unit Mounting holes Alternative mounting holes Cable feed through Alternative areas for the cable feed through Dimensional diagram of the mounting bracket II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 23 The alternative fastening points serve to use already available mounting holes from other input units so that no new holes for the attachment must be made on the exterior of the safe. The mounting bracket can be fixed with at least two M5 screws via the alternative fixing points. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 24 (bus cable A --> A-OUT, bus cable B ---> B-OUT). Unscrew set bolt “C” of the input unit until the end of the set bolt is level with the upper part of mounting clip “D”. A-OUT B-OUT Connecting bus cables “A” and “B” II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 25 Screw set bolt “C” through the open battery compartment and tighten by hand until the input unit is securely attached to the mounting surface. Mounting and attaching the input unit Customer Service CLAVIS Deutschland GmbH Grüner Weg 38 34117 Kassel Telefon: +49 (0)561 988 499-0 E-Mail: info@tresore.eu Internet: www.tresore.eu www.tresorschloss.de PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 26: Mounting The Locks

    Lock class B/C (according to EN 1300) or class 2/3 (according to VdS 2396) – Lock class D (according to EN 1300) or class 4 (according to VdS 2396) Important: per locking system only locks with the same class must be used! II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 27 Dimensional diagram of the lock (dimensions in mm) bolt stroke 8.7 bolt stroke 12 bolt stroke 14 bolt stroke 15 open bolt protrudes 1.2 mm 18.6 ø10 ø6.6 66.6 7 7.8 30.9 30.6 Dimensional diagram of the lock PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 28 Minimum usable thread length of 5 mm. 6 6 . Hexagon socket head screw M6x25 (8.8) or longer Screws must be secured against loosening (e.g. with LOCTITE 243 blue, medium strength) Mounting the lock II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 29 The M5x12 M4x12 lock bolt must also have some play in the end positions. Mounting the carrier adapter PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 30: Mounting The Door Bolt/Door Position Contacts

    (if provided) must remain electrically separated (galvanically separated). However, a mechanical coupling, for example by common activation of the switches, is permissible. Mandatory Optional Door position contact A Door bolt contact A First door lock Door position contact B Door bolt contact B Connecting the door bolt/door position contacts II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 31: Mounting The Inner Compartment Locks

    4.5 “Mounting the door bolt/door position contacts”. The bus cables to the inner compartment locks must be led and placed suitably. Kinking, shearing and inadvertent pulling out of the cables must unconditionally be avoided. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 32: Mounting The Optional I/O-Box

    A connection diagram for the various in- and outputs is provided in section 5. Dimensional diagram of the I/O-Box (dimensions in mm) Dimensional diagram of the I/O-Box II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 33 Attach the I/O-Box to the inside of the door body with four M5 hexagon socket head screws (or the equivalent in inches) (screw length according to local conditions). The tightening torque must not exceed 200 Ncm at a minimum usable screwing depth of 6 mm. Mounting the I/O-Box PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 34 If the red time lock interruption key is pressed the time lock is interrupted for 2 minutes. Lock chamber casing ø 10 mm Pin for activating the time lock interruption key (not included in scope of supply) Drill hole for the time lock interruption key II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 35: Installation And Commissioning Of The Optional Cover "Vds Blocking Element" For The I/O-Box

    When the locks and door bolt contacts are open, the “Locking status” signal output of the hazard alert or intrusion detection system indicates that the locking system is unlocked. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 36: Connection Work

    12...24 VDC 700 ... 200 mA – Locking status Remote locking signal (positioning of the contacts with remote locking activated) 6.8 kΩ Connection diagram for operating the locking system Paxos advance as a blocking element (factory configuration) II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 37 “VdS blocking element” is removed and thus indicates a tampering incident to the locking system. Functionality of input 4: External tamper input Contact open: Cover “VdS blocking element” removed Contact closed: Cover “VdS blocking element” mounted correctly (lifting contact positioned on the I/O-Box) PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 38: Mounting The Cover "Vds Blocking Element

    Installation Installation Instructions 4.8.4 Mounting the cover “VdS blocking element” Dimensional diagram of the cover “VdS blocking element” II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 39 Carefully place the cover “VdS blocking element” on the I/O-Box, ensuring that the cable of the lifting contact does not get caught under the proximity switch. Attach the cover “VdS blocking element” with both of the M5 hexagonal socket head screws. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 40 If the red time lock interruption key is pressed the time lock is interrupted for 2 minutes. Lock chamber casing ø 10 mm ø 2.5 mm pin for activating the time lock interruption key (not included in scope of supply) Drill hole for the time lock interruption key II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 41: Commissioning

    The remote lock function is automatically deactivated by deleting master code MA1. Customer Service CLAVIS Deutschland GmbH Grüner Weg 38 34117 Kassel Telefon: +49 (0)561 988 499-0 E-Mail: info@tresore.eu Internet: www.tresore.eu www.tresorschloss.de PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 42: Mounting Of The Optional Ip-Box

    IP network with an Ethernet cable. You can find a schematic diagram for the different inputs and outputs in chapter 5. IP-Box dimensions diagram (measurements in mm) Dimensional diagram of the IP-Box II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 43 Installation Instructions Installation IP-Box cover dimensions diagram (dimensions in mm) Dimensional diagram of the IP-Box cover PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 44 Put on the IP-Box cover and engage it in the retaining burls of the four fixing lugs. Fix cover with at least two of the M2.5 hexagon socket head screws provided diagonally to the fixing lugs. Mounting the IP-Box II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 45 If the red time lock interruption key is pressed the time lock is interrupted for 2 minutes. Lock chamber cover ø 10 mm Pin for the activation of the time lock interruption key (not delivered) Drill hole for the time lock interruption key PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 46: Using The Ip-Box For The Operation As Blocking Element

    When the locks and door bolt contacts are open, the “Locking status” signal output of the hazard alert or intrusion detection system indicates that the locking system is unlocked. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 47: 4.10.3 Connection Work, Alarm System

    700 ... 200 mA – Locking status Remote locking signal (positioning of the contacts with remote locking activated) 6.8 kΩ Connection diagram for operating the locking system Paxos advance as a blocking element (factory configuration) PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 48 IP-Box (terminals 1 and 2) in accordance with the diagram. Functionality of input 1: Remote lock Contact open: Remote lock activated Contact closed: Remote lock deactivated II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 49: Electrical Installation

    The plug must be inserted carefully, accurately and precisely to ensure a safe electrical connection is provided. Carefully pull on the wire to disconnect any plug connections. Customer Service CLAVIS Deutschland GmbH Grüner Weg 38 34117 Kassel Telefon: +49 (0)561 988 499-0 E-Mail: info@tresore.eu Internet: www.tresore.eu www.tresorschloss.de PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 50: Connecting The Input Unit, Locks, I/O-Box And Ip-Box With The Bus Cable

    /K e /D ia 2 (B C la 3 (C C la A - OUT B - IN B - OUT 6 (E /K e /D ia 2 (B C la 3 (C C la Bus wiring II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 51: External Connections On The I/O-Box

    The I/O-Box functions are only available in its entirety, if the I/O-Box is connected to an external power supply. In case of a power failure the batteries in the input unit ensure the lock functions over a limited period of time, but not the entire functions of the I/O-Box. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 52: I/O-Box Connection Data

    Output 6 normally closed) can be changed Standard: Duress alarm static via the AS384 Management-Suite 37 (OUT7) / 38 (OUT7) Output 7 Software, if the standard (see Standard: Battery compartment description in the table) does not open apply. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 53 The AS384 Management-Suite Software can be used to reconfigure the functions of the in- and outputs. Additionally, it can be specified which inputs must be connected via the tamper monitoring circuit (only input 1 is configured for the connection of a tamper monitoring circuit at the factory). PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 54: External Connections To The Ip-Box

    14 15 7 8 9 10 1 2 3 4 5 7 mm IP-Box terminal assignment and Ethernet interface Note on network safety: It is recommended to operate the lock systems (IP-Boxes) only within protected firm networks. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 55: Ip-Box Connection Data

    Max. 0.3 A at 50°C ext. IP-Box OUTx OUTx Note: the standard setting (NC: normally closed) can be changed via the AS384 Management-Suite Software, if the standard (see description in the table) does not apply. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 56 (ex work, only input 1 is configured for connection to a tamper monitoring circuit). In addition, with the AS384 Management-Suite Software the Paxos advance locking system can be configured for use with an IP network. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 57: Addressing/Functional Check Of The System

    Insert the batteries/rechargeable battery pack and/or switch on the external power supply Batteries must be inserted into the battery pack based on the markings – observe the polarity. The battery pack or dorma+kaba rechargeable battery pack must then be inserted into the battery compartment (only one position possible).
  • Page 58 (counterclockwise) and then to the right (clockwise). The ser- vice code input will appear. Enter the service code “4714” via the keypad or dial knob. Confirm the code with the <ENTER> key or by pressing the dial knob. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 59 “0010203040“ with ID+PIN mode) via the keypad or dial knob. Confirm the code with the <ENTER> key or by pressing the dial knob. The system status “Unlocked” is displayed. The system is now addressed. Then complete a functional check. PAXOS advance Series II_PAXOS_V001_20161007_EN...
  • Page 60 If there are more door locks, the code input for the next door lock is automatically displayed. Repeat step 5 for all of the other door locks. Once all of the door locks are open, you will be prompted to open the boltwork. Open the boltwork and the message “Unlocked” is displayed. II_PAXOS_V001_20161007_EN PAXOS advance Series...
  • Page 61 “10203040” (“0010203040“ with ID+PIN mode). Fur- ther information is included in the Operating Manual for Paxos advance. Customer Service CLAVIS Deutschland GmbH Grüner Weg 38 34117 Kassel Telefon: +49 (0)561 988 499-0 E-Mail: info@tresore.eu Internet: www.tresore.eu www.tresorschloss.de PAXOS advance Series II_PAXOS_V001_20161007_EN...

Table of Contents