Fujitsu Waterstage WOYG160LJL Installation Manual page 62

Air to water heat pump split single service, refrigerant r410a inverter, outdoor/hydraulic unit
Hide thumbs Also See for Waterstage WOYG160LJL:
Table of Contents

Advertisement

Line
Function
6201
S
Reset sensors
S
6205
Reset to default parameters
6220
S
Software version (RVS)
S
Info 1 OEM
6300
6301
S
Info 2 OEM
LPB system
S
6600
Device address
Error
U
Reset Defaut relais
6710
6711
U
Reset HP
6800
S
History 1
S
6802
History 2
6804
S
History 3
S
History 4
6806
6808
S
History 5
S
History 6
6810
S
6812
History 7
6814
S
History 8
S
History 9
6816
6818
S
History 10
Maintenance / special regime
S
7070
HP interval
7071
S
HP time since maint
Reset ? (no, yes)
7073
S
Cur starts compr1/hrs run (since the 6 last weeks)
Reset ? (no, yes)
7141
U
Emergency operation
Off: Heat pump functions normally (with boosters if necessary).
On: Heat pump uses the electric boost system or the boiler connection.
Use the "On" position only in Assist mode or Test mode: may result in high power bills.
7142
S
Emergency operating function type
Manual: Emergency mode is not active when a fault occurs (Emergency mode = OFF).
Automatic: Emergency mode is active when a fault occurs (Emergency mode = ON).
In "Automatic" position, the energy cost can be onerous if the error is not detected and eliminated.
7150
I
Simulation outdoor temp
- 62 -
Setting range
or display
No, Yes
No, Yes
0... 99
0... 65535
0... 65535
0... 16
No, Yes
No, Yes
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
Time, Date, Error code
--, 1... 240
0... 240
0... 12
Off, On
Manual, Automatic
-50... 50 °C
Setting
Basic
increment
setting
1 month
1 month
Manual
0.5
Waterstage / Installation / 2011 - EN
No
No
--
--
--
1
No
No
--
0
0
Off
--