Room Influence; Flow Temp Setpoint Min; Room Temperature Limitation - Fujitsu Waterstage WOYG160LJL Installation Manual

Air to water heat pump split single service, refrigerant r410a inverter, outdoor/hydraulic unit
Hide thumbs Also See for Waterstage WOYG160LJL:
Table of Contents

Advertisement

Line
Function
S

Room influence

928
If the installation is fitted with a room thermostat:
This function enables you to choose the ambient temperature's influence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
932
S
Room temp limitation
S
Mixing valve decrease
938
941
S
Actuator running time
963
S
With prim contr / system pump
*Basic setting : 1 circuit = No ; 2 circuits = Yes.
Heating adjustment, Circuit 2
Only with the 2nd circuit kit option (If the installation consists of 2 heating circuits).
1010
U
Comfort setpoint
1012
U
Reduced setpoint
1014
U
Frost protection setpoint
S
Comfort setpoint maximum
1016
I
1020
Heating curve slope
(see
"Recommended settings for the parameters depending on the installation's emitters", page 50
I
Off-set of the heating curve
1021
1030
I
Summer / Winter heating limits
When the average of the outdoor temperatures over the past 24 hours reaches 18°C, the regulator switches off the
heating (as an economy measure). During summer mode, the display shows "Eco". This function is only active in
automatic mode.
1040
I

Flow temp setpoint min

(with dynamic radiator, adjust from 30 to 35°C)
I
1041
Flow temp setpoint max
Floor heating system = 50 °C / Radiators = 65 °C.
Important Note : Maximum temperature limitation is not a safety function as required by ground heating.
1050
S
Room influence
If the installation is fitted with a room thermostat:
This function enables you to choose the ambient temperature's influence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
S
1060

Room temperature limitation

As soon as the room temperature = [Setpoint line 1010 (ex. 20°C) + Room temperature limitation setpoint line 1060
(ex. 0,5 °C)] > 20,5 °C => The heat pump is stopped.
It restarts when the room temperature falls below the setpoint (in the example, Room temperature < 20,0 °C).
1080
S
Quick setback
1090
S
Optimum start control max
1091
S
Optimum stop control max
S
1100
Reduced setpoint increase start
1101
S
Reduced setpoint increase end
S
Mixer valve increase
1130
1134
S
Actuator running time
Waterstage / Installation / 2011 - EN
Setting range
or display
1... 100 %
0,5... 4 °C
0... 20 °C
30... 873 s
No, Yes
Reduced setpoint...
Comfort setpoint maximum
Frost protection setpoint...
Comfort setpoint
4 °C... Reduced setpoint
Comfort temp... 35 °C
0.1... 4
(fig. 38, page 49)
-4.5... 4.5 °C
8... 30 °C
8... 70 °C
8... 70 °C
1 %... 100 %
0.5... 4 °C
Off, Down to reduced setpoint,
Down to frost prot setpoint
0... 360 min
0... 360 min
-30... 10 °C, --°C
-30... 10 °C, --°C
0... 50 °C
30... 873 s
Setting
Basic
increment
setting
1 %
80 %
0,5 °C
0,5 °C
1 °C
0 °C
1 s
240 s
No*
0.5 °C
20 °C
0.5 °C
19 °C
0.5 °C
8 °C
1 °C
28 °C
0.02
0.5
&
fig. 37, page
49)
0.5 °C
0 °C
0.5 °C
18 °C
1 °C
17 °C
1 °C
60 °C
1 %
50 %
0.5 °C
0.5 °C
Off
10 min
180 min
10 min
30 min
1 °C
--
1 °C
-5 °C
1 °C
0 °C
1 s
240 s
- 55 -