Floor Curing Function; Floor Curing Setpoint Manually; If The Installation Is Fitted With The Cooling Kit - Fujitsu Waterstage WOYG160LJL Installation Manual

Air to water heat pump split single service, refrigerant r410a inverter, outdoor/hydraulic unit
Hide thumbs Also See for Waterstage WOYG160LJL:
Table of Contents

Advertisement

Line
Function
850
I

Floor curing function

- Off: Early interruption of the current programme, programme inactive.
- Operational heating.
- Heating ready for occupation.
- Operational heating + ready heating.
- Ready heating + operational heating.
- Manual: Manual mode enables you to programme your own concrete slab drying time.The function ends
automatically after 25 days.
55
50
45
40
35
30
25
20
0 1
5
X
Heating ready for occupation
1
Operational heating + Heating ready for occupation
fig. 40 - Diagram of the concrete slab drying programmes
I
851

Floor curing setpoint manually

(if line 850 = manual)
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying programme stops automatically after running for 25 days.
I
856
Floor curing day current
857
I
Floor curing day completed
S
900
Operating mode changeover
Operating mode at end of concrete slab drying period
Cooling circuit 1
If the installation is fitted with the cooling kit (Only with the cooling kit option).
U
901
Operating mode
902
U
Comfort cooling setpoint
903
U
Reduced setpoint
I
908
Flow temp setp at OT° 25°C
909
I
Flow temp setp at OT° 35°C
I
Cooling limit at OT°
912
913
S
Lock time at end of heating / cooling
918
S
Summer comp start at OT°
S
919
Summer comp end at OT°
920
S
Summer comp setp increase
S
Flow temp setp min OT° 25°C
923
924
S
Flow temp setp min OT° 35°C
- 54 -
(fig.
40)
10
18 1
Operational
heating
Setting range
or display
Please
standards
of the manufacturer of the
building ! A good performance
of this function is only possible
with an installation correctly
implemented
electricity and adjustments) !
This function can be stopped
by anticipation when setting the
5
7
adjustment on "Off".
Day
25
0... 95 °C
0... 32
0... 32
None, Protection mode,
Reduced, Comfort, Automatic
Protection, Automatic, Reduced,
Comfort
17... 40 °C
5... 40°C
6... 35 °C
6... 35 °C
8... 35 °C
8... 100
20... 50 °C
20... 50 °C
1... 10 °C
6... 35 °C
6... 35 °C
Setting
Basic
increment
setting
comply
with
and
instructions
(hydraulic,
1 °C
25 °C
1
Reduced
Protection
0,5 °C
24 °C
26 °C
0,5 °C
20 °C
0,5 °C
16 °C
0,5 °C
24 °C
1 h
24 h
1 °C
26 °C
1 °C
40 °C
1 °C
4 °C
0.5 °C
18 °C
0.5 °C
18 °C
Waterstage / Installation / 2011 - EN