Siemens SIMATIC IPC1047 Operating Instructions Manual page 58

Hide thumbs Also See for SIMATIC IPC1047:
Table of Contents

Advertisement

Expanding and assigning parameters to the device
6.4 Drives
Procedure
Read section "ESD guideline (Page 103)".
Removal
1. Place the tray with the drive (nameplate) on the bottom on the mounting base as shown
in the figure.
In the following figure, the installation in vertical format is shown on the left and the
installation in horizontal format on the right.
2. Unscrew the highlighted screws.
3. Lift up the tray and place it on the mounting base next to the drive.
Installation
1. Place the drive next to the tray as shown. Make sure that the threads and holes are even.
2. Touching only the sides of the drive, move it left into the tray while keeping it even.
3. Fix the drive and tray in position at the center and carefully turn both over: the drive
(rating plate) faces downward, see figure above.
Ensure that each hole of the tray is positioned exactly over the threads of the drive.
4. Screw on the drive from behind. Do not tighten the screws too much. Do not exceed the
maximum tightening torque of 0.7 Nm.
58
Operating Instructions, 09/2018, A5E45118479-AA
SIMATIC IPC1047

Advertisement

Table of Contents
loading

Table of Contents