Control Terminal Wiring; Connection Diagram - Invertek Drives OPTIDRIVE P2 Series Easy Start Up Manual

Table of Contents

Advertisement

4.8. C
Control Term
minal Wiring
All analog sig
gnal cables shou
Power and C
Control Signal ca
Signal levels 
of different volt
Maximum co
ontrol terminal t
Control Cabl
le entry conduct
4.9. C
Connection 
Diagram 
4.9.1. Pow
wer Terminal D
Incomin
ng Mains Power S
Supply 
For 1 Ph
hase Supply, conn
ect to 
L1/L an
d L2/N terminals. 
For 3 Ph
hase Supply, conn
ect to 
L1, L2 &
& L3 terminals. 
Phase s
sequence is not 
importa
ant. 
Protect
tive Earth / Ground
connec
tion. 
The driv
ve must be Earthe
ed / 
Ground
ded 
4.9.2. Con
ntrol Terminal 
 
Open 
+24V Su
upply (100mA) / E
External Input 
Digital 
Input 1 
Stop 
Digital 
Input 2 
Forw
ard Rotation 
Digital 
Input 3 
Analo
og Speed Ref 
Digital 
Inputs : 8 – 30 Vol
t DC 
+ 10 Vo
olt, 10mA Output 
Analog 
Input 1 
 
Analog 
Output : 0 – 10 Vo
olt / 4‐20mA, 20m
0 Volt S
Supply / External 
Input 
Analog 
Input 2 
Analog 
Output : 0 – 10 Vo
olt / 4‐20mA, 20m
SAFE TO
OQUE OFF input 
"STO"Electric
Also ref
fer to section 4.10
0.7 
Logic H
igh = 18‐30 Vdc ("
"SAFE TORQUE OF
mode) 
Relay C
Contacts (Terminal
s 14‐18) 
250VAC
C / 30VDC 
5A Max
ximum 
 
Op
ptidrive ODP‐2 U
User Guide Revis
uld be suitably sh
hielded. Twisted
d pair cables are 
ables should be r
routed separate
tages e.g. 24 Vo
lt DC and 110 Vo
 
tightening torqu
ue is 0.5Nm.
2
tor size: 0.05 – 2
2.5mm
 / 30 – 12
2 AWG.
Designations 
L1 / L 
L2 / N
L3 
l Connections &
& Factory Setti
Closed 
Run (Enable) 
Reverse Rotation 
R
Preset Speed 
mA Max 
mA Max 
cal Installation
 
F" Standby 
 
sion 1.30 
recommended.
ly where possib
le, and must not
t be routed para
olt AC, should no
ot be routed in t
the same cable.
 
ings 
+24V
DIN1
DIN2
DIN3
+10V
AIN1
7
0V 
0V
 
AOU
UT1 
0V 
0V
10 
AIN2
11
 
AOU
UT2 
12 
STO+
13
STO‐
14 
 
RL1
‐C 
15
 
RL1‐
NO 
16 
 
RL1‐
NC 
17 
 
RL2
‐A 
18 
 
RL2
‐B 
allel to each othe
er. 
 
Motor
 Connections
Conne
ct the motor to th
he U, V & W 
termin
nals. 
The mo
otor earth must be
connec
cted to the drive 
Option
nal Brake Resistor
 & DC Bus 
Conne
ctions 
Where
e a Brake resistor i
s used, it 
must b
be connected to th
he BR and 
DC+ te
erminals 
 
 
Outp
put Speed 
Outp
put Current 
 
Defa
ault 
Func
ction :  
Heal
lthy 
/ Fau
ult 
Defa
ault 
Func
ction :  
Runn
ning 

Hide quick links: