Safety guidelines

Safe handling

CAUTION: Use this equipment in a manner specified by the manufacturer: failure to do this may cancel the
protection provided by the equipment.
For new enclosures, prepare the site for installation per
safe-handling instructions provided in
Unplug the enclosure before you move it, or if you think that it has become damaged in any way.
A safe lifting height without a mechanical lift is 20U (~35").
The 4U106 ships with all FRUs other than the discs installed; however, the DISCs must be installed as part of
the system setup, after the enclosure is securely mounted in the rack.
Before installing the enclosure into a rack, see the WARNING on
After installing the enclosure, and before installing the DISCs, see
To install DISC drive modules into a rack-mounted enclosure, face the front panel, and pull the enclosure
outward on its rails. Remove the top cover(s) to provide access to the DISC module slots. See
(page 22)
module slot indexing. See also
The belt straps and optional lift handles are designed to support the weight of the enclosure as shipped. Neither
safely supports a fully populated enclosure. See also
CAUTION: Use a suitable mechanical lift for hoisting the enclosure for installation into the rack:
Fully configured Exos E 4U106 enclosures can weigh up to ~131 kg (289 lb). Do not install DISCs until after
the enclosure is secured into the rack.
When positioning the enclosure into its rack space, use the belt straps (quantity three) or the optional enclosure
lift handles (two handles per side). See also
information.
Observe the lifting hazard label affixed to the storage enclosure.
Do not use vacuum lift because it can potentially damage the 4U106 enclosure.

Operation

IMPORTANT: It is essential that all FRU slots hold modules or module blanks to use the enclosure for more than
the allowed service times for a FRU module.
Observe the caution label affixed to the module being replaced.
Replace a defective FRU with a fully operational FRU as soon as possible. Do not remove a defective FRU
module unless you have a replacement model of the correct type ready for insertion.
Before removal/replacement of a PSU, disconnect supply power from the PSU to be replaced. Refer to
"Replacing a PSU module" (page
Observe the hazardous voltage warning label affixed to power supply modules.
12
Safety guidelines
"Unpacking the enclosure" (page
for removable lids, and see
"Installing an LFF drive carrier module" (page
74).
"Installation checklist" (page
Figure 10 (page 23)
and
Figure 11 (page 23)
"Unpacking the enclosure" (page
"Requirements for rackmount installation" (page 43)
35), and follow
37).
page
44.
"ESD precautions" (page
for DISC slots and FRU
84).
37).
73).
Figure 9
for additional

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents