Alignment Of The Discharge Side; Adjusting The Roller Pressure - ProMinent Dulco flex DFBa Series Operating Instructions Manual

Peristaltic pump
Table of Contents

Advertisement

4.3.3

Alignment of the discharge side

4.3.4

Adjusting the roller pressure

Fig. 2: Space plates / roller
6
Spacer plates
9
Roller
Transport, storage, assembly and Installation
The discharge line is to be kept as straight and short as possible,
in order to avoid performance reduction.
The diameter must correspond to the rated diameter of the pump
hose. A larger diameter is recommended in the event of viscose
liquids.
It is recommended to use a flexible transition between two fixed
pipes and the hydraulic connection of the pump, in order to avoid
the transmission of vibrations.
The peristaltic pump is equipped with spacer plates (6), in order to
adjust the precise pressure distance to the roller (9) (dependent on
speed and operating pressure).
P_DX_0013_SW
23