Alignment Of The Discharge Side; Adjusting The Roller Pressure - ProMinent DULCO flex DFCa Operating Instructions Manual

Peristaltic pump
Hide thumbs Also See for DULCO flex DFCa:
Table of Contents

Advertisement

Transport, storage, assembly and Installation

4.3.3 Alignment of the discharge side

4.3.4 Adjusting the roller pressure

Fig. 2: Space plates / roller
6
Spacer plates
9
Roller
24
The discharge line is to be kept as straight and short as possible,
in order to avoid performance reduction.
The diameter must correspond to the rated diameter of the pump
hose. Bei viskosen Flüssigkeiten wird ein größerer Durchmesser
empfohlen.
It is recommended to use a flexible transition between two fixed
pipes and the hydraulic connection of the pump, in order to avoid
the transmission of vibrations.
The peristaltic pump is equipped with spacer plates (6) to adjust
the precise pressure distance to the roller (9) (dependent on speed
and operating pressure).
P_DX_0013_SW

Advertisement

Table of Contents
loading