Fronius Agilo 360.0-3 TL Operating Instructions Manual page 71

Grid-connected inverter

Advertisement

Available languages

Available languages

Status LT
The status display of the most recent inverter fault can be displayed.
IMPORTANT! Due to the low level of insolation early in the morning and in the evening,
the status codes 306 (Power low) and 307 (DC low) are displayed routinely at these times
of day. These status messages do not indicate any kind of fault.
-
-
-
Grid Status
The five most recent grid faults can be displayed:
-
-
-
Fan test
To check that the fan is working correctly
Unit
Setting range
Factory setting
The fan test is started by pressing the 'Enter' key.
While the test is ongoing, its ' Progress' is shown on the display.
OK
Fail
Version
Displays the version and serial numbers of the PC boards in the inverter (e.g. for service
purposes)
Unit
Display area
Factory setting
Press the 'Enter' key to see the status of the power stage set and the most recent fault
Use the 'Up' and 'Down' keys to scroll through the list
Press the 'Back' key to close the status and fault list
Press the 'Enter' key to see the five most recent grid faults
Use the 'Up' and 'Down' keys to scroll through the list
Press the 'Back' key to close the grid fault display
-
Start (Progress)
-
Fan test successful
Fan is defective; the associated status code is displayed in 'NOW' view mode.
-
Display / Display Software / Interface / SmartMedia Card / Con-
trol / Control Software / Monitoring / Monitoring Software / Inter-
face
-