Chapter 1 Maintenance
6. Enter the file path you have written down in Step 1 in Enter the file location of the new firmware text
box, and select Activate.
BMC firmware update starts.
When update is completed, the following message is output on syslog.
kernel: EVLOG: INFORMATION - BMC nn/120, firmware burn succeeded.
7. If the BMC firmware update of one PCI module is completed, select another PCI module, stop and start.
8. When it is necessary to replace it to return primary and the secondary of PCI module to an original state,
stop PCI module of the primary side and start.
When the following error message is displayed, check the file location of the new firmware.
Tips
•
The length of the file name must be between 1 and 255 characters.
•
Update file does not exist.
Express5800/R320c-E4, R320c-M4 Maintenance Guide (Linux)
4. Maintenance of the Server
41