Chapter 3 Useful Features
Option
POST Error Pause
AC-LINK
Power On Delay Time
The table below shows the operation of DC power when the AC power is turned off once and then back on, in
accordance with the AC LINK setting.
System status before AC power was turned off
Operating (DC power is ON)
Abort (DC power is also OFF)
Forced shutdown*
* Continue pressing the POWER switch for at least 4 seconds to forcibly turn off the power.
162
Parameter
[Disabled]
Enabled
Stay Off
[Last State]
Power On
[50]-600
If an uninterruptible power supply (UPS) is used for automatic operation, set the
Tips
AC-LINK to Power On.
Express5800/R320c-E4, R320c-M4 Maintenance Guide (Linux)
Descriptions
Enable or disable the feature to suppress OS booting when
POST detects an error.
Specify AC link feature. Specify how the DC power state
should be when the AC power is supplied again after loss
of power. (See the table below)
If Power On or Last State is selected, the system starts
after the time specified for Power On Delay Time has
elapsed and CPU/IO modules of both systems are installed
(180 seconds at longest).
Specify the DC power-on delay time when Power On or
Last State is selected for AC-LINK (Unit: second).
AC LINK setting
Stay Off
Last State
Off
On
Off
Off
Off
Off
1. System BIOS
[
]: Factory settings
Power On
On
On
On
Need help?
Do you have a question about the Express5800/R320c-E4 and is the answer not in the manual?
Questions and answers