Connecting The Actuators - Festo CPI-CL Series Manual

Compact performance
Table of Contents

Advertisement

5. Output module type CP−A08−M12−EL−Z

5.4.2 Connecting the actuators

1
Pin allocation
Port x1
1: n.c.
2: Ax+1
3: 0 V
4: Ax
5: FE
5
Internal connection in module
Fig. 5/5: Pin allocation type CP−A08−M12−EL−Z
5−10
For connecting the actuators, use plugs and cables with M12
union nut from the Festo range (see Appendix A.6).
Tighten the plugs with the aid of the union nut in order to
·
prevent unintentional loosening, e.g. due to shock.
Seal unused connections with the protective caps sup
·
plied. Only in this way can you comply with protection
class IP65.
Pin allocation
The following diagram shows as an example the pin allocation
of the actuator connections on the CPI output module.
1
5
Port x1
2
Pin allocation
Port x2
1: n.c.
2: n.c.
3: 0 V
4: Ax+1
5: FE
2
3
Port x2
Port x3
3
Pin allocation
Port x3
1: n.c.
2: Ax+3
3: 0 V
4: Ax+2
5: FE
n.c.= (not connected)
AX = output x
5
4
Port x4
4
Pin allocation
Port x4
1: n.c.
2: n.c.
3: 0 V
4: Ax+3
5: FE
Festo P.BE−CPEA−CL−EN en 0711a

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents