Cisco BWX 8305 Installation And Commissioning Manual page 69

Table of Contents

Advertisement

Chapter 6
Installation
Note
Note
From the PC, go to Start > Programs > Accessories > TeraTerm > TerTerm, or using whichever
Step 7
terminal emulation program you are running.
Note
In the COM1 Properties window (reference
Step 8
configuration options. Click "OK".
Figure 6-34
Power on the BWX 8303 Basestation Timing System unit. The DC model has an "on/off" switch and the AC
Step 9
model does not, simply plug in the AC power cord. The Power light illuninates. The Fault light will be
on until the GPS satellite acquisition is finished, and the Lock light will blink. When the unit acquires
its satellites, the fault light will go off, and the Lock light will be solid. Verify at the terminal
workstation, that the BXW 8303 Basestation Timing System is communicating. (Refer to
OL-16336-02
The BWX 8303 Basestation Timing System unit will assign its own IP address, or a console
command can be used to turn on DHCP, and the Service Provider's network can assign an IP
address. Refer to the BWX 8303 Basestaion Timing System Operation & Maintenance Manual
for console commands.
The BWX 8303 Basestation Timing System unit will not send alarms to the EMS. Change the
SNMP to send error messages from the BWX 8303 Basestation Timing System unit to a NMS
server (or other IP Address as required).
A VT 100 terminal or any standard Windows-based ASCII terminal emulation program can be
used for connecting to the Console port. The connection for TeraTerm is explained here as an
illustrative example. The steps to get to the TeraTerm program may be different due to variances
between Operating Systems and in the PC setup. The TeraTerm program can be downloaded free
from the Internet.
COM1 Properties
Connect BWX 8303 Basestation Timing System
Figure
6-34), under the Port settings tab enter the
Bits per second:
Bits per second:
Bits per second:
Bits per second:
57600
57600
Data Bits:
Data Bits:
Data Bits:
Data Bits:
8
8
8
8
Parity:
Parity:
Parity:
Parity:
None
None
None
None
Stop Bits:
Stop Bits:
Stop Bits:
Stop Bits:
1
1
1
1
Flow Control:
Flow Control:
Flow Control:
Flow Control:
None
None
None
None
BWX 2305 Basestation Installation and Commissioning Guide
Example
6-1)
6-33