BWX 8305 Basestation Antenna Installation
6.3.8.2 Enter BWX 8305 Basestation Antenna Data
The CD that accompanies the antenna contains an HTML file (under the RFS folder).
Open the WiMAX I&C closeout Tool (should be open from the Cable Sweeps). Click on the "RFS and
Cable RFS loss" tab. Press the "Insert RFS data" button. When prompted to open a file, find the HTML
file under the RFS folder in the CD, and click "Open". This will automatically populate the top half of
the tab. See
Figure 6-17

6.3.9 Connect Bundled Cables to BWX 8305 Basestation Antenna

6.3.9.1 Types of Cable
All BS cable connections are made using standard RF coaxial cable. In
various coaxial cables sold in the United States. Note that the RG-6 or RG-11 bundled cable contains 8
antenna element cables and a Calibration ("Cal") cable. Reducing several single cables into one bundled
cable makes installation easier and helps eliminate power loss through the cables.
The bundled cable comes with a weatherized boot and 9 N-type connectors in place. At the other end the
connectors can be N-type if the cables are to be connected to surge protectors in the bus bar (Primary
Surge Protection), or QMA-type connectors if the cables are to be connected directly to the BS
(Secondary Protection only). Examples are shown in
jumper cables are needed to connect the surge protectors in the bus bar to the BS.
BWX 2305 Basestation Installation and Commissioning Guide
6-18
Figure
6-17.
RFS & Cable Loss (Top Half of Worksheet)
Figure 6-18
Figure
6-19. In the first case, N-type to QMA-type
Chapter 6
Installation
are examples of
OL-16336-02