Summary of Contents for Valor Heartbeat Oxysafe 426
Page 1
THIS APPLIANCE THIS APPLIANCE IS FOR USE IN IS FOR USE WITH THE UNITED NATURAL KINGDOM (GB) (G20) AT A SUPPLY PRESSURE THE REPUBLIC 20mbar (8in w.g.) OF IRELAND (IE) R A D I A N T / C O N V E C T O R G A S F I R E M O D E L 4 2 6 ( G C 3 2 8 1 1 4 0 ) INSTALLATION &...
APPLIANCE DATA This product uses a fuel effect piece containing General Data Refractory Ceramic Fibres (RCF), which are man-made The overall dimensions are shown in fig.1. vitreous silicate fibres. Excessive exposure to this Gas: Natural (G20) material may cause temporary irritation to eyes, skin and respiratory tract.
The fireplace opening must be within the following In the United Kingdom, as supplied, the dimensions: appliance can be installed in the following situations. Width: Max. 423mm 2.3.1 Conventional fireplace and hearth Min: 305mm The appliance can be installed to a fireplace complete Height Max: 610mm* with surround and hearth...
Page 5
25mm with a minimum clearance of 50mm between its 2.10. open end and the nearest obstruction. The minimum allowable distance to a corner There must also be a minimum clearance of 165mm wall or any other projection at either side of the between the back of the closure plate and the back of the appliance is 100mm.
UNPACKING & PRE-INSTALLATION PREPARATION 3.1. Carton Contents 3.3. Appliance Preparation The carton contains the following:- 3.3.1. Stand the fire upright. Fire assembly. 3.3.2. Detach the window surround (See figure 4): Ceramic fuel effect (In packaging inside Remove the two knurled screws immediately firebox).
3.3.4. 3.3.8. Remove the control bezel by unscrewing two Check ignition spark screws (see fig.5). Before attempting to install, it is worth checking that the piezo electric spark ignition system operates satisfactorily. To initiate the spark, temporarily refit the control knob to the tap spindle.
3.3.9.2 opening by 25mm. Make sure that the rectangular air Fit the feet to the underside of the appliance relief openings are fully within the fireplace opening. feet mounting brackets (See figure 9). Fig. 9 Foot to bracket assembly (left side shown) 3.3.10 Fit the flue spigot to the back of the fire using Fig.
APPLIANCE INSTALLATION Installing To A Hearth 4.2.2 4.1.1. Drill and plug the holes. Fit a woodscrew in The levelling screw lock nuts should be one hole. Leave about 12mm gap between the screw accessible below the shrouds. If necessary, loosen the head and the wall to hang the fire.
FULL OPERATING CHECKS Check Control Settings 5.1.5. Check all the control settings. These are:- 5.1.1. Knob To help in checking the control positions while Position Burner appearance the outer case is detached, place the control bezel over 1/IGN Centre section on low. Outer the gas tap spindle and against the tap bracket.
This monitoring system, or any of its parts, must only be exchanged using Valor authorised parts. FINAL REVIEW replace the window unit for cleaning the inside of the Make sure that the floor plate has been refitted.
SERVICING & PARTS REPLACEMENT • Always turn off the gas supply and make sure that the located behind the vertical face of the back panel but in front of the two rearward angled ears near the top appliance is cool before commencing any servicing. corners of the back panel.
8.5. To Remove The Burner, Pipes And 8.7. To Disconnect The Gas Supply Pipe Pilot Access for gas supply disconnection, may be easier if the floor plate is removed. 8.5.1. Remove the outer case as section 8.2. 8.7.1. Remove the outer case as section 8.2. 8.5.2.
REPLACEMENT PARTS - SHORT LIST DESCRIPTION No. OFF MAKERS PART Injector - Upper - Bray 99 Size 150b 522109 Injector - Bray 99 Size 240 522809 Gas Tap Copreci & Spark Generator 558799 Spark Generator 521069 Pilot Unit 545949 Inlet Elbow 532519 Window Unit 522209...