This Owner Guide is intended to help you care for your Valor gas fire.
Please read carefully before using your gas fire and keep for future reference.
This Owner Guide gives sufficient details to enable your gas fire to be operated and
maintained.
IMPORTANT.
Please keep your Owner Guide in a safe place together with the
Installer Guide.
600A738/02

Advertisement

Table of Contents
loading

Summary of Contents for Valor 495

  • Page 1 Code 4950 - Charcoal Case with Coals Code 4951 - Autumn Brown Case with Logs This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep for future reference.
  • Page 2: Table Of Contents

    In the United Kingdom If you require further assistance or any advice about gas in general, the Valor AdviceLine will be pleased to help.
  • Page 3: Safety

    SAFETY • Soft wall coverings (e.g. embossed vinyls etc.) are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this is mind when having a heating appliance installed and when redecorating. •...
  • Page 4: General Specification

    Thank you for choosing this Valor gas fire. It has been designed to give years of trouble-free service. To maintain its optimum performance, advantage should be taken of the regular servicing and inspection facilities available for gas appliances. These instructions are provided to help you in operating and looking after your new fire and should be kept in a safe place together with the installation and servicing instructions for future reference.
  • Page 5: Operatio

    3 minutes before attempting to relight. If the monitoring system starts to shut off the gas frequently please get expert advice. In the United Kingdom call the Valor AdviceLine on 0345 626341 (local call rates apply). To light the pilot...
  • Page 6: Turning Off

    To turn off 2.6.1 To turn the main and decorative flames off but leaving the pilot alight, depress the control knob partially, turn clockwise to IGN and release the knob. 2.6.2 To turn the pilot off, depress the control knob partially at the IGN position, turn clockwise to OFF and release the knob.
  • Page 7: Cleaning

    CLEANING All cleaning should be carried out when the fire is cold. Normally, the fire should only need dusting. Any stains on the glass can be removed with a non abrasive cleaner such as a ceramic hob cleaner. Abrasive cleaners should never be used. Cleaning the inside of the window: 3.1.1 Detach the window trim by sliding its side channels upwards to clear the location brackets on the window frame...
  • Page 8 4.1.2 Position the front centre coal (embossed "B" on its underside) in the well in the coal bed marked "B" - see figure 8. The narrow "nose" should locate in the "U" shaped valley at the front of the coal bed.
  • Page 9 4.1.4 Position the rear right coal (embossed "D" on its underside) in the well in the coal bed marked "D" - see figure 10. The pointed rear of the coal should rest on the ledge in the "V" cut-out at the rear of the well in the coal bed marked "D".
  • Page 10: Log Effects

    Log Installation 4.2.1 Place the rear log (the log with only one short stub) in the retaining cradle behind the rear burner tube with its back against the firebox back wall (Fig.12). The short stub should be at the top right of the log. Centre the log so that the gap to the firebox walls is the same at each side.
  • Page 11: Servicing & Maintenance

    Serial Number This will be found on a label on the right hand side of the case near the bottom. f) The fault, problem or request. General advice about gas and your gas fire: VALOR ADVICELINE 0345 626341. To report faults or arrange for your fire to be serviced: VALOR SERVICE 0121 386 6203.
  • Page 12: Safety First