Now you can see the lamp, fixed into its position by means of a "locking slider".
•
Push the locking slider to the right.
•
Withdraw the lamp module. While withdrawing, the plug is disconnected.
•
When the lamp is removed, you see the two guiding rods on the upper right/lower left and the additional
fan for cooling.
Barco - OverView D series - Doc-3353-2 - user's manual - Revision 04 - April 2005
7. Maintenance and servicing
guiding rods and additional fan, lamp module with plug
_______________________________________________________________________
Figure 7-11
Position of slider
Figure 7-12
Locking slider
Figure 7-13
withdrawing the lamp module
Figure 7-14
7-14