PROBLEM
Zone Mode Problems:
Zone Alarms not detected by the
7845CZ.
The 7845CZ causes a bell fault
when wired to the bell output of the
control panel.
9–4
PROBABLE CAUSE
Ground not connected between
the control panel and the
7845CZ.
Zone setting does not match its
physical connection
configuration.
Incorrect zone setting.
SOLUTION
Check all wiring and make sure
the GND terminal of the radio is
connected the control panel's
signal ground not earth ground.
Make sure that the program-
med setting EOLR, V+, or V-
matches the wired connection
to Z1.
Make sure that for + bell outputs,
the 7845CZ is set for V+ trigger,
and that for – bell outputs, it is set
for V- trigger.