Question 46.
Question 47.
Question 48.
Question 49.
Question 50.
Question 51.
Question 52.
Question 53.

Reviewing Programming Entries

When the last question is answered, the system validates all entries. If no errors are found,
the following is displayed:
To review the programming options (to ensure that the correct responses have been made),
press [Y]. The programming questions are displayed again, starting with Question 1. Use
the up/down arrow keys to scroll through the program fields without changing any of the
values. If a value requires change, simply type in the correct value. When the last field is
displayed, the "REVIEW?" question again appears.

Setting Factory Defaults

Reset the programming options to factory-default values by pressing [ESC] at the
"REVIEW?" prompt. A confirmation prompt appears. Press [Y] to reset, or press [N] to cancel
this function. If you press [Y], all programmed values are reset to the original factory
settings.

Exiting Programming Mode

To exit the programming mode, press [N] in response to the "REVIEW?" question.
5–10
Press [Y] to enable reporting to second central station for
2CS Zone 5 (Y/N)
zone 5.
Press [N] to disable reporting.
Press [Y] to enable reporting to second central station for
2CS Zone 6 (Y/N)
zone 6.
Press [N] to disable reporting.
Press [Y] to enable reporting to second central station for
2CS Zone 7 (Y/N)
zone 7.
Press [N] to disable reporting.
Press [Y] to enable tamper reporting to second central
2CS Tamper (Y/N)
station.
Press [N] to disable reporting.
Press [Y] to enable reporting of system report to second
2CS Sys Rpt (Y/N)
central station.
Press [N] to disable reporting.
Enter the secondary city code 2-digit ID (01-99 decimal).
2nd City
This ID number combined with the CS ID and the
Subscriber ID must be different from the ones
programmed in Questions 1 through 3 (Primary Account
Information).
Enter the second central station's system ID number, 01-
2nd CS ID
FE. This ID number combined with the City ID and the
Subscriber ID must be different from the ones
programmed in Questions 1 through 3 (Primary Account
Information).
Enter the4-digit customer account number for the second
2nd Sub ID #
central station, 0001-9999. This ID number combined with
the City ID and the CS ID, must be different from the ones
programmed in Questions 2 through 4 (Primary Account
Information).