ADEMCO 7845CZ Installation And Setup Manual page 48

Seven zone cellular control channel transceiver
Table of Contents

Advertisement

7845CZ Installation and Setup Guide
[D]
[S]
Zone Input Status Display Interpretation for [S] Command
1234567
System Status Display Interpretation for [S] Command
8–2
Battery = 6.2V
1234567TmDcB Flt
55555555 + + 0
The status of Zones 1 – 7 are reported in the ADEMCO High-Speed format.
1 New Event*
2 New Opening*
3 Restore*
* Will probably not be displayed due to speed of radio
Tm
Tamper status follows high-speed format codes above.
Dc
Represents line voltage:
+
V
^
B
Represents battery condition:
+
V
C
Flt
Represents Radio Faults:
0
VSWR
PLL
Battery Test
This selection initiates a battery test. The charger is
removed from the battery and a load is applied. The
measured battery voltage is then displayed.
Status Display
The status of the 7845CZ can be viewed on the 7720P.
The status display includes:
zone input status
Tm - tamper status
Dc - charging voltage status
B - battery condition
Flt - radio fault status.
3 will be an X not a 5 if Lynx Panic = N
4 New Closing*
5 Normal
6 Previously Reported Event
DC line voltage OK
DC line voltage bad and reported
DC line voltage bad, not reported (reporting window not
expired)
DC voltage restored, not reported as restored
Battery voltage acceptable
Battery voltage below 5.7V, +/-5%, under transmit load with
AC present.
Or
Battery voltage below 5.8V, +/-5%, under transmit load
during AC loss.
Battery voltage going low has not yet been sent to the central
station (appears only briefly).
Battery low radio in current limit mode. No transmissions
can be sent.
Normal – No Fault
No contact with AlarmNet (check antenna, connections)
Hardware failure; requires factory service
X Zone Not Enabled