ADEMCO 7845CZ Installation And Setup Manual page 53

Seven zone cellular control channel transceiver
Table of Contents

Advertisement

PROBLEM
Communications Problems:
7845CZ will not transmit a message
to the Cellular network. Red radio
status LED blinking after each
transmission attempt, rapid-blinks
constantly, or on all the time.
7845CZ does not come out of
carrier search mode.
Intermittent failure to supervise
alarms (com-fails) received,
followed by an eventual restore.
Intermittent radio fault
indications.
Failure to supervise alarm with
no restores.
Radio fault with no restore.
PROBABLE CAUSE
Poor cellular coverage.
Antenna improperly installed.
Antenna located near metallic
object, steel studs, wire lath
plaster walls, etc.
Installation site unsuitable for
indoor antenna.
Current limit = Y with a low or
no battery.
Poor cellular coverage, antenna
installation or location.
Installation site has obstructions
that come and go, such as steel
rollup security gates and large
trucks parked close to the
antenna over night.
If this is a one-time event, and
the 7845CZ is installed in an
area where it only sees one
Cell site, the site could have
been down for maintenance.
7845CZ has failed or lost
power.
Radio coverage has faded due
to poor initial installation, or
new obstructions at the
installation.
Section 9: Troubleshooting
SOLUTION
It's all about coverage
Recheck installation per the
"selecting a radio installation
site" paragraph in Section 4 .
Move the 7845CZ until RSSI
level and transmission success
rates are acceptable.
Check that the antenna has
been properly installed, and
that the connector is not
damaged.
Move 7845CZ away from
interfering object.
Use 7825-OC antenna kit to
mount the antenna outside.
Connect a fully charged battery
to the 7845CZ.
See startup Problems section.
Recheck installation procedure
in the "Selecting a Radio
Installation Site" paragraph in
Section 4 . Move the 7845CZ
until RSSI level and
transmission success rates are
acceptable. Check antenna and
power connections.
Check the installation site for
obstructions, and move the
7845CZ to deal with them. Site
testing should be done in the
worst-case configuration (i.e.,
rollup gate or garage door
down, etc.).
Nothing can be done for this
problem, and although rare, It
can happen.
Check 7845CZ for proper
operation and that power
source is functioning.
Check the installation site for
obstructions, and move the
7845CZ to deal with them. Site
testing should be done in the
worst-case configuration (i.e.,
rollup gate or garage door
down, etc.).
9–3