Setting The Microphone - Sony HDCU1000 Installation Manual

Hd camera control unit
Hide thumbs Also See for HDCU1000:
Table of Contents

Advertisement

2-3-2. Setting the Microphone

HDCU1000/1080/1500 can output the two independent
microphone lines (MIC 1, MIC 2) of video camera
HDC1000 series as it receives these MIC signals.
Controlling the Microphone Input Gain Using the
Remote Control
HDCU1000/1080/1500 can adjust the input gain of the
MIC connector of camera HDC1000 series using the
remote control in the range of 60 dB to 20 dB in 10 dB
steps using either of the following methods.
1. Adjusting the microphone input gain to be set
from MENU
When the MIC REMOTE connector on the rear panel is
connected to nothing or the levels of pin-8 (MIC 1) and
pin-15 (MIC 2) of the MIC REMOTE connector are High,
the microphone input gain can be adjusted from CHU MIC
*
GAIN on page "C04"
of the configuration menu.
Factory setting : (60 dB)
2. Adjusting the microphone input gain using
the MIC REMOTE connector
Set the microphone input gain control to ON or OFF with
pin-8 and pin-15 of the MIC REMOTE connector on the
rear as shown below. The input gain can be controlled via
pin-5, pin-6 and pin-7 as shown below.
Setting the microphone input control of the video camera
Pin No.
Microphone connector
8
15
MIC IN CH-1
L
L
ON
L
H
ON
H
L
OFF
H
H
Internal setup (Menu page "C04"
Setting the microphone input gain of the video camera
Input gain
7
60 dB
H
50 dB
L
40 dB
H
30 dB
L
20 dB
H
H : +5 V or OPEN
L : GND
Input resistance : Pulled-up 100 kZ +5 V
The setup for the HDCU-700A mode is shown in parenthesis ( ) :
S406-2/AT-167 → ON
. IM/HDCU1000 Series
MIC IN CH-2
ON
OFF
ON
*
)
Pin No.
6
5
H
H
H
H
L (H)
H (L)
L (H)
H (L)
H (L)
L (H)
3. Adjusting the MIC signal phase
When the microphone signal phase is ahead of the video
signal phase to be used, adjust the amount of audio delay
from MIC OUT DELAY on page "C04"
tion menu.
Factory setting : 0 Fs
Setting the Microphone Output Level
S500
S501
1 1
RV500
RV501
Select the microphone output signal level (0 dB, _20 dBu)
from the MIC 1, 2 connector on the rear using the switches
on the AVP-6 board.
. Setting the output level of MIC 1 :
Switch S500 (MIC 1 OUT LEVEL)
. Setting the output level of MIC 2 :
Switch S501 (MIC 2 OUT LEVEL)
. Factory setting : 0 dBu (both S500 and S501)
The microphone output signal level from the MIC 1, 2
connector on the rear can be adjusted using the volume on
the AVP-6 board.
. Setting the output level of MIC 1 :
1RV500 (MIC 1 OUT LEVEL)
. Setting the output level of MIC 2 :
1RV501 (MIC 2 OUT LEVEL)
* : "C05" in software V1.10 or later
*
of the configura-
AVP-6 board (A side)
2-19 (E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdcu1500Hdcu1080Hkcu1001Hkcu1005Hkcu1003

Table of Contents