Ref.No.
Name
S405
V-DLY
S406
MODE1
1
MIC-GT 1&2/1,2
2
MIC-G7 STD/700
3
D-SUB MIC/WFM For switching the D-SUB-15P function on HDCU1500
4
ASPECT RMT/PNL ON: Accepts the switching command last input from MSU when the ASPECT
5
6
CNU/RM
7
RCP-PX ENB/DIS Sets the monitor selection control method for PIX OUT by RCP.
8
MONI-S M&R/RCP
1-14 (E)
Function
Video phase setting between HD and SD
Sets the phase difference (delay time) between the HD signal and the SD
signal output from CCU.
The phase can be advanced as follows based on the delay time set with S410.
HD standard: 128ck (27 MHz) increment
SD standard: 256ck (74 MHz) increment
S407
REFERENCE HD
Reference (advance amount
of SD)
0
0
_4.74 usec
1
2
_9.48 usec
3
_14.2 usec
4
_19.0 usec
5
_23.7 usec
_28.4 usec
6
7
_33.2 usec
8
_37.9 usec
9
_42.7 usec
A
_47.7 usec
B
_52.1 usec
C
_56.9 usec
D
_61.6 usec
E
_66.3 usec
F
_71.1 usec
1H 525 : 63.5 usec
1125-60i : 29.6 usec
625 : 64.0 usec
1125-50i : 35.6 usec
1125-24 PsF : 37.0 usec
Sets whether or not to control MIC1 and MIC2 of the MIC GAIN CONTROL pin of the
MIC REMOTE connector independently or by interlocking the MIC1 and MIC2 controls.
ON: MIC1, MIC2 independent control
OFF: MIC1, MIC2 interlocked control
For switching the interface specification of MIC-Remote (D-SUB-15P)
ON: Old interface (700 mode)
OFF: Standard-I/F
ON: WFM-Remote
OFF: MIC-Remote
switching from outside (D-Sub) is valid.
OFF: Does not accept the command input from MSU when the ASPECT
switching from outside (D-Sub) is valid.
Not used
For setting the priority of remote device on HDCU1500 hen the
Front-PNL-RM (RM-B750) is installed
ON: Front-PNL-RM has priority.
OFF: Device connected to the Rear-RM-CMD connector has priority.
ON : Only WF can be controlled from RCP.
OFF : Both PIX and WF can be controlled from RCP.
Sets the monitor selection control method for PIX/WF OUT.
ON : Can only be controlled from RCP (PIX/WF 1 system). When there is
PIX/WF 2 system, it can be controlled from MSU.
OFF : Can be controlled from either MSU or RCP. (Latest priority)
REFERENCE SD
Reference (advance amount
of HD)
0
_3.45 usec
_6.70 usec
_10.3 usec
_13.8 usec
_17.2 usec
_20.7 usec
_24.1 usec
_27.6 usec
_31.0 usec
_34.5 usec
_37.9 usec
_41.4 usec
_44.8 usec
_48.3 usec
_51.7 usec
750-60P : 22.2 usec
750-50P : 26.7 usec
MIC1 : 5 pin to 7 pin
MIC2 : 12 pin to 14 pin
MIC1, MIC2 : 5 pin to 7 pin
Factory default setting
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
. IM/HDCU1000 Series