Example Of Setting The Select Button Functions - Sony BKS-R1617 Operation Manual

Multi display control unit
Hide thumbs Also See for BKS-R1617:
Table of Contents

Advertisement

Several crosspoints switchable with the touch
of a button (phantom function or sarvo
function)
When multiple crosspoints have been set as a phantom
on the control terminal, all the crosspoints defined with
a phantom name can be switched by pressing one
button.
Connectable with a single cable
The unit can be connected to the Sony routing
switchers using a single 75-ohm coaxial cable, and can
control the switchers.
Status display function
The currently selected source name, destination name,
and any error messages are displayed in the display
window.
Self-diagnostic function
When the power is turned on, the unit automatically
checks communication on the S-BUS data link, and the
buttons on the front panel, which light in succession.
The results appear in the display window.
Operation on various voltages
The unit can operate on voltage between 100 V and
240 V AC without voltage adaptation.
Example of Setting the Select
Button Functions
The select buttons can be used as either source select
buttons or destination select buttons. The control
terminal or the setup function of this unit allows you to
define the function of each button. The settings are
made for each button.
For details on making settings on the control terminal, refer
to the Installation Manual supplied with the routing
switcher.
Expanding the number of sources and
destinations
You may expand the controllable number of sources
and destinations using two or more control units as a
block. When you use multiple control units in
combination, define one of them as the mother unit,
and the others as the daughter units in a block. A
switching system can include up to 10 blocks and up to
253 remote control units in total. The controllable
number of sources and destinations depends on the
number of control units used in a system.
Note
If you control only a single destination, it is not
necessary to define a mother unit and daughter units.