PARAMETERS FOR FLOOR SCREED DRYING

Group F1 contains the parameters for the setting of floor screed drying.
The procedure for F parameters setting is the same as the procedure for service
settings (see 38).
Table with descriptions of parametres:
Para-
Parameter name
meter
F1.1
FLOOR DRYING
F1.2
INTERVAL 1: DURATION
F1.3
INTERVAL 1: START TEMPERATURE
F1.4
INTERVAL 1: END TEMPERATURE
F1.5
INTERVAL 2: DURATION
F1.6
INTERVAL 2: START TEMPERATURE
F1.7
INTERVAL 2: END TEMPERATURE
F1.8
INTERVAL 3: DURATION
F1.9
INTERVAL 3: START TEMPERATURE
F1.10
INTERVAL 3: END TEMPERATURE
F1.11
INTERVAL 4: DURATION
F1.12
INTERVAL 4: START TEMPERATURE
F1.13
INTERVAL 4: END TEMPERATURE
Floor screed drying profile - factory setting:
Service setting manual
50
Setting range
Default
setting
0- NO
0
1- CIRCUIT 1
2- CIRCUIT 2
3- CIRCUIT 1 & 2
1 ÷ 15 days
10
20
10 ÷ 60 °C
10 ÷ 60 °C
20
1 ÷ 15 days
5
10 ÷ 60 °C
20
10 ÷ 60 °C
50
1 ÷ 15 days
10
10 ÷ 60 °C
50
10 ÷ 60 °C
50
1 ÷ 15 days
5
50
10 ÷ 60 °C
10 ÷ 60 °C
20