7. Application Examples
Parameter
No.
4-10
5-10
5-11
5-40
8-03
8-04
8-10
8-50
8-51
8-52
8-53
8-54
8-55
8-56
10-01
7
10-02
10-10
10-12
7.1.1. Example of PLC Programming
In this example Instance 101/151 is placed in the following Input/Output address:
Input ad-
dress
Set-up
70
Function
Motor speed range/direction
Digital input 18
Digital input 19
Function relay
Control word timeout time
Control word timeout function
Control word profile
Coasting select
Quick-stop select
DC-brake select
Start select
Reversing select
Set-up select
Preset reference select
Baud rate select
MAC ID
Process data type selection
Process Data Config Read
0.0-0.15
0.16-0.31
1.0-1.15
1.16-1.31
Status
MAV
Motor tor-
Digital in-
word
que
put
MG.33.D3.02 - VLT
Setting
Both directions [2]
No operation [0]
Reversing [10]
Control word bit 11 [36]
Control word bit 12 [37]
1.0 sec
Stop [2]
FC Profile
Bus [1]
Bus [1]
Bus [1]
Bus [1]
Logic AND [2]
Bus [1]
Bus [1]
- set to match other DeviceNet stations
- set desired station address
Instance 101/151 [1]
PCD 3: Torque
PCD 4: Digital input
®
is a registered Danfoss trademark
FC 100/ 200/ 300 DeviceNet