Bosch Rexroth AG
Mounting, demounting and electric installation
10.2 Mounting notes for built-in devices
Provide a space of 50 mm on all sides of the device for sufficient cooling and
●
cable routing
The LED display on the operator panel must not be covered
●
Wire all cables in loops. Use strain reliefs for all cables
●
Install the operator display only vertically, with a max. deviation of ±45°,
●
measured from the vertical
10.3 Mounting the built-in devices
To mount the operator display, proceed as follows:
Loss of degree of protection IP 65!
The housing, in which the operating display is installed, has to fulfill
the following conditions:
Free from impurities
●
Sufficient mechanical strength and flatness
●
These criteria influence the required IP degree of protection to a
great extent.
Further required measures have to be taken depending on the
mounting location, e. g. the stabilization of the mounting frame.
1. Prepare a mounting cut-out, refer to
the built-in devices" on page
2. Insert the operator display from the front into the cut-out until the latching
lug at the top of the device latches in the cut-out.
24/49
chapter 10.4 "Mounting dimensions of
27.
VEP 07.6/15.6 Multi Touch
DOK-SUPPL*-VEPXX.6MTHU-IT01-EN-P