Vep 07.6/15.6 multi touch operator display-housing devices and built-in devices
Table of Contents

Advertisement

Bosch Rexroth AG
Interfaces
Pin
Function
1
S1 (E-STOP) N/C contact 1
2
S1 (E-STOP) N/C contact 1
3
S1 (E-STOP) N/C contact 2
4
S1 (E-STOP) N/C contact 2
5
S2 (white key), N/O contact / N/C contact
6
S2 (white key) N/O contact
7
S2 (white key) N/C contact
8
S3 (black key), N/O contact / N/C contact
9
S3 (black key) N/O contact
10
S3 (black key) N/C contact
Tab. 9-8: Pin assignment X3
NOTICE
For terminal connectors use copper wire only. Tighten the screws of the screw
terminals with a torque of 2.25 lb in (0.25 Nm).
20/49
Destruction of screw terminals, insufficient con-
tact and loss of UL/CSA certificiation if no cop-
per wire is used and/or wrong tightening tor-
que.