Mounting the Module

5.1

General Information

5.2

Mounting Notes

5.3

Required Tools and Accessories for Mounting

The S67-DO8-HS-M12 module can be fastened directly to the system using
screws. It can also be mounted on a mounting rail using an adapter or fas‐
tened to a profile rail using a mounting profile.
For mounting on a flat surface, Bosch Rexroth offers spacers as mounting
aid; the spacers can be inserted between the IndraControl S67 components.
This helps by providing sufficient mounting distance for compact direct
mounting, as well as eliminating gaps where dirt could accumulate. A cable
tie can be fastened through each of two eyebolts in the spacer, which togeth‐
er serve as strain relieve from the actuator cables.
The following information shall always be observed:
Disconnect the power supply from the system before starting the instal‐
lation.
The maximum drilling hole diameter for the fastening holes of the field
bus coupler must not exceed 4 mm. Otherwise, there may be no full
contact with the PE socket of the S67-DO8-HS-M12 module and correct
shielding is not possible.
To protect the S67-DO8-HS-M12 module from tensile forces that may
arise, do not bridge spaces with the module
Screw the S67-DO8-HS-M12 module down only on flat contact surfaces
to protect the module from warping
Ensure that the connectors are not soiled during mounting. Dirt dam‐
ages the contacts, which can cause corrosion in these areas
To avoid damaging the S67-DO8-HS-M12 module, do not mount the
module in shear areas of moving devices.
Provide sufficient potential equalization in the system
Use all fastening holes to mount the S67-DO8-HS-M12 module to the
system so that all FE connections lie on a ground potential.
Depending on the mounting type, the following tools are required for installa‐
tion:
A screwdriver for M4 fastening screws
Drilling machine to pre-drill the fastening holes for mounting on the sys‐
tem for the S67-DO8-HS-M12 module and, if required for the imperfora‐
ted mounting rails
M4 thread cutter (bottoming tap or hand tap set)
The Bosch Rexroth accessories listed below are required for mounting. The
associated order numbers are listed in
51.
Mounting rail adapter including fastening screws and perforated or non-
perforated mounting rails (TS 35 x 7.5 rail) according to EN 60715
or
Profile adapter, including fastening screws
Bosch Rexroth AG
Mounting the Module
chapter 12 "Accessories" on page