Mounting The Vep 15.6 Housing Devices; Mounting Notes - Bosch Rexroth IndraControl Operating Instructions Manual

Vep 07.6/15.6 multi touch operator display-housing devices and built-in devices
Table of Contents

Advertisement

Bosch Rexroth AG
Mounting, demounting and electric installation

10.6 Mounting the VEP 15.6 housing devices

10.6.1 Mounting notes

When mounting the embedded terminal, ensure an ergonomic operation. Ad-
ditionally, ensure that all moving machine components can be seen by the op-
erator at any time!
Avoid mounting locations exposed to direct sunlight, as the screen readability
is reduced and additional heat development can occur.
When mounting the embedded terminal, ensure an easy access to the connec-
tor panel (top side).
Provide a minimum space of 50 mm (on all sides of the device) for sufficient
cooling and for cable routing
Lay all connecting cables in loops and use strain reliefs for all cables
Keep as much distance as possible to noise sources
To maintain the degree of protection, use only cable grommets that fit to the
cable cross-sections for the cable bushing
Fig. 10-10: Cable bushing
Remove the cover at the rear side of the device to connect the cables. Re-
move the screws of the cover (see ② in
page
29) and then remove the cover.
Connect all cables
After connecting all the cables, tighten the screws of the cover again
Observe that the sealing of the cover is not damaged
Mount the cover correctly and fasten the screws with the correct mounting
torque
WARNING
Ensure that the cover is mounted before switching on the device.
28/49
fig. 10-11 "Position of the cover" on
If the cover is open, the specified degree of pro-
tection is not given anymore!