6.3

Interface description

6.3.1

Overview

DRIVE-CLiQ Extension (DQE) has two connections for the S120M hybrid connector as well as
a connection for DRIVE-CLiQ.
The DRIVE-CLiQ signals of the incoming hybrid line are terminated and the DRIVE-CLiQ
signals of the DRIVE-CLiQ cable are fed into the new hybrid line. All other connections are only
looped through from the inputs to the outputs.
Figure 6-1
Note
The X1 (input) and X2 (output) connections must not be interchanged.
6.3.2

Hybrid connector

Connecting the hybrid cable from the S120M of the previous line
Table 6-1
Manual, 06/2019, 6SL3097-5AW00-0BP1
Block diagram of DRIVE-CLiQ Extension
Terminal strip X1 (IN)
Terminal
Signal name
1
1 (TXP)
2
2 (RXP)
3
3 (TXN)
4
4 (RXN)
5
PE
6
M
7
+
8
DCN
9
DCP
-
DQ_SHIELD
DRIVE-CLiQ Extension
6.3 Interface description
Technical data
Transmit data +
Receive data +
Transmit data -
Receive data -
Potential equalization
Electronics ground
48 VDC power supply
DC link voltage - (M600)
DC link voltage + (P600)
Shield
111