Siemens Sinamics S120M Equipment Manual page 60

Distributed drive technology
Hide thumbs Also See for Sinamics S120M:
Table of Contents

Advertisement

Adapter Module 600
4.2 Safety instructions for Adapter Modules
Electric shock due to missing DC link side covers
There is a danger of an electric shock through contact when the side covers of the DC link are
missing.
● Mount the side covers on the first and last component in the drive line-up.
You can order missing side covers (article number: 6SL3162-5AA00-0AA0).
NOTICE
Damage caused by the use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system if incorrect or unapproved
DRIVE-CLiQ cables or hybrid cables are used.
● Only use suitable DRIVE-CLiQ cables and hybrid cables that have been approved by
58
WARNING
Siemens for the respective application.
Manual, 06/2019, 6SL3097-5AW00-0BP1

Advertisement