Troubleshooting Table - Receiving Units; Fault Table - Center Pole Head Control Lamp - Wacker Neuson DPU80 Series Operator's Manual

Table of Contents

Advertisement

10.2
Troubleshooting table – receiving units
Fault
Receiver units light up yellow.
Machine does not respond to
commands from the remote control.
Receiver units flash yellow in rapid
succession. Machine does not
respond to commands from the
remote control.
Receiver units light up red.
Receiver units flash red.
*
Have this work performed by the service department of your Wacker Neuson contact partner.
10.3

Fault table - Center pole head control lamp

Fault
The control lamp illuminates red.
The control lamp flashes red.
100_0202_ts_0010.fm
Possible causes
Remote control is switched off.
Rechargeable battery of the
remote control is discharged.
Remote control is defective.
Operator is outside of the receiving
area.
No clear line of sight between the
remote control and receiver unit.
Receiving units or remote control is
dirty.
Decoder, receiver unit, or electrical
connection is defective.
Operator is located in the proximity
area.
Machine is in the warm-up phase.
Diagnostic system has detected an
error.
Machine is overloaded because
the soil cannot be compacted any
further.
Possible causes
Machine is in the warm-up phase.
Diagnostic system has detected an
error.
Machine is overloaded because
the soil cannot be compacted any
further.
10 Troubleshooting
Remedial measure
Switch on remote control unit.
Load or replace rechargeable
battery of the remote control.
Have remote control replaced or
repaired.*
Enter the receiving area of the
machine.
Establish a clear line of sight with
the receiving unit.
Clean remote control and receiving
units.
Have the machine repaired.*
Leave the proximity area of the
machine.
Wait until the warm-up phase has
completed.
Check control lamps and fault
indications on the display.
Avoid operation on non-
compactable soil.
Reduce the compaction
performance by actuating the
slow / fast rocker switch.
Switch-over from fast to slow
operation.
Remedial measure
Wait until the warm-up phase has
completed.
Check control lamps and fault
indications on the display.
Avoid operation on non-
compactable soil.
Reduce the compaction
performance by actuating the
slow / fast rocker switch.
Switch-over from fast to slow
operation.
53