Simple Data Setting - YASKAWA VS-606V7 Series Instruction Manual

Compact general-purpose inverter
Hide thumbs Also See for VS-606V7 Series:
Table of Contents

Advertisement

• Simple Data Setting

Digital setting (Refer to 5, OPERATING THE INVERTER) and potentiometer setting
are both available for simple accel/decel operation of the VS-606V7.
Frequency reference by analog voltage is set with initial setting (n004 = 1). For the
model with digital operator (with potentiometer) JVOP-140, factory setting is set by
frequency setting potentiometer (n004=0).
Following is an example in which the function LED's are used to set frequency
reference, acceleration time, deceleration time, and motor direction.
Data setting by frequency setting potentiometer
1. Turn the potentiometer fully to the left. Then, turn
the power ON.
2. F/R blinks.
Select FWD/REV run using keys.
Never select REV when reverse run is
prohibited.
NOTE
3. Press DSPL to blink FREF. Then press RUN.
4. Operates the motor by turning the potentiometer
to the right. (Frequency reference corresponds to
the potentiometer position is displayed.)
If the potentiometer is switched rapidly,
NOTE
the motor also accelerates or decelerates
rapidly corresponding to the
potentiometer movement. Pay attention
to load status and switch the
potentiometer movement.
Status indicator lamp
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Operator
Operation Steps
Display
0.00
FOR
or
REV
0.00
00.0 to
60.00
Minimum
output
frequency is
1.50Hz
: ON
: Blinking (Long Blinking)
12-LED
Status
Display
Indicator LED
RUN
FREF
ALARM
RUN
F/R
ALARM
RUN
FREF
ALARM
RUN
FREF
ALARM
:OFF
: Blinking
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents