Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
YASKAWA Manuals
Inverter
VS-606V7 Series
Instruction manual
YASKAWA VS-606V7 Series Instruction Manual page 97
Compact general-purpose inverter
Hide thumbs
Also See for VS-606V7 Series
:
Instruction manual
(176 pages)
,
Instruction manual
(223 pages)
,
Connection manual
(64 pages)
YASKAWA
VS-606V7 Series
Instruction Manual
1
2
3
4
5
6
7
8
9
10
11
12
Table Of Contents
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
page
of
176
Go
/
176
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
• Read out holding register contents [03H]
Reads out the contents of the holding registers with the continuous numbers for the
specified quantity. The contents of holding register is divided into the upper 8 bits
and the lower 8 bits. They become the data items in response message in the order
of numbers.
Example: Reads out status signal, fault contents, data link status and frequency
reference from the VS-606V7 (slave 2).
Reference message
(at normal operation)
Slave address
Function code
Upper
Start
number
Lower
Upper
Quantity
Lower
Upper
CRC-16
Lower
(For error code 03H, refer to
page 99.)
* Twice as much as the number of reference message.
• Example of loop-back test [08H]
Command message is returned as a response message without being changed. This
function is used to check transmission between the master and the slave. Any
arbitrary values can be used for test codes or data.
Example: Loop-back test of slave 1 and VS-606V7
Reference message
(at normal operation)
Slave address
01H
Function code
08H
Upper
00H
Start
number
Lower
00H
Upper
A5H
Quantity
Lower
37H
Upper
DAH
CRC-16
Lower
8DH
96
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Response message
(at normal operation)
02H
Slave address
02H
03H
Function code
03H
00H
Number of data*
08H
First
20H
Upper
00H
CRC-16
holding
00H
Lower
65H
resistor
04H
Next
Upper
00H
holding
45H
Lower
00H
resistor
F0H
Next
Upper
00H
holding
Lower
00H
resistor
Next
Upper
1H
holding
Lower
F4H
resistor
Upper
AFH
CRC-16
Lower
82H
Response message
(at normal operation)
Slave address
01H
Function code
08H
Upper
00H
Start
number
Lower
00H
CRC-16
Upper
A5H
Quantity
Lower
37H
Upper
DAH
CRC-16
Lower
8DH
Reference message
(at fault occurrence)
Slave address
02H
Function code
83H
Error code
03H
Upper
F1H
Lower
31H
Reference message
(at fault occurrence)
Slave address
01H
Function code
89H
Error code
01H
Upper
86H
Lower
50H
Table of
Contents
Previous
Page
Next
Page
1
...
94
95
96
97
98
99
100
101
Show Quick Links
Quick Links:
Parameter Set-Up and Initialization
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for YASKAWA VS-606V7 Series
Inverter YASKAWA VS-606V7 Series Instruction Manual
Compact general-purpose inverter (voltage vector control) (223 pages)
Inverter YASKAWA VS-606V7 Series Instruction Manual
Compact general-purpose inverter (voltage vector control) (176 pages)
Inverter YASKAWA Varispeed F7 Connection Manual
Inverter sio driver (64 pages)
Inverter Yaskawa VS-626M5 Instruction Manual
Vector-controlled inverter drives with power regenerative function for machine tools (305 pages)
Inverter Yaskawa Varispeed-606PC3 Instruction Manual
Ultra-compact all-digital low-noise inverter (158 pages)
Inverter YASKAWA VS mini C Series Instruction Manual
Ultra-compact all digital inverter, advanced function type (78 pages)
Inverter YASKAWA VS mini C Series Instruction Manual
Ultra-compact all digital inverter (77 pages)
Inverter YASKAWA VS mini C Series Instruction Manual
Ultra-compact all digital inverter advanced function type (77 pages)
Inverter YASKAWA VS mini C Series Instruction Manual
Ultra-compact all digital inverter advanced function type (77 pages)
Inverter YASKAWA VS?616G5 Owner's Manual
Yaskawa vs?616g5 inverter owner's manual (84 pages)
Inverter YASKAWA Varispeed-676 Instruction Manual
Transistor inverter (69 pages)
Inverter YASKAWA VS mini J7 Series Instruction Manual
Vs mini j7 series compact general-purpose inverter (119 pages)
Inverter YASKAWA VS MINI J7 Series Instruction Manual
Compact general-purpose inverter (voltage vector control) (118 pages)
Inverter YASKAWA V1000 Replacing Manual
Procedure for replacing the v1000 with the ga500 (35 pages)
Inverter YASKAWA Varispeed G7 Instruction Manual
General purpose inverter (advanced vector control) (499 pages)
Inverter YASKAWA Varispeed V7 Instruction Manual
Compact general-purpose inverter (256 pages)
Related Products for YASKAWA VS-606V7 Series
Yaskawa VS-626M5
Yaskawa VS-656MR5
YASKAWA VS-616G5 Series
YASKAWA VS-686SS5
YASKAWA VS mini C Series
YASKAWA VS MINI J7 series
YASKAWA VS mini V7
Yaskawa Varispeed-606PC3
YASKAWA Varispeed-676
Yaskawa VARISPEED-626M5
Yaskawa VARISPEED-626MR5
YASKAWA Varispeed G7 Series
YASKAWA Varispeed AC
YASKAWA VARISPEED-616G5
YASKAWA Varispeed V7 Series
YASKAWA Varispeed V7
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL