Simple Data Setting

Digital setting (Refer to 5. OPERATING THE INVERTER) and
potentiometer setting are both available for simple accel/decel operation of
the VS-606V7.
Digital setting is set at the factory (n004=1). For the model with digital
operator (with potentiometer) JVOP-140, factory setting is set by frequency
setting potentiometer (n004=0).
Following is an example in which the function LED's are used to set
frequency reference, acceleration time, deceleration time, and motor
direction.
Data setting by frequency setting potentiometer
Operation Steps
1. Turn the potentiometer fully to the left. Then,
turn the power ON.
2. F/R blinks.
Select FWD/REV run using keys.
Never select REV when reverse run is
NOTE
prohibited.
3. Press DSPL to blink FREF. Then press RUN.
4. Operates the motor by turning the
potentiometer to the right. (Frequency
reference corresponds to the potentiometer
position is displayed.)
NOTE
If the potentiometer is switched rapidly,
the motor also accelerates or decelerate
rapidly
corresponding
potentiometer movement. Pay attention
to load status and switch the
potentiometer with the speed not to affect
motor movement.
Status indicator lamp
40
Operator
Display
0.00
FOR
or
REV
0.00
0.00 to 60.00
Minimum
output
frequency is
1.50Hz
to
the
: ON
: Blinking
Status
12-LED
Indicator
Display
LED
FREF
RUN
ALARM
RUN
F/R
ALARM
RUN
FREF
ALARM
RUN
FREF
ALARM
: OFF