Parameter
No.
n176
Parameter copy function selection
• Prohibiting Parameter Read Selection (n177)
Select this function to prevent accidentally overwriting the parameters stored in
EEPROM or in the digital operator. Reading is not possible when this parameter is set
to 0.
The parameter data is stored in the digital operator are safe from accidental
overwriting.
When reading is performed while this parameter is set to 0, PrE will blink. Press the
DSPL or ENTER and return to the parameter No. display.
Parameter
No.
n177
Read function
Reads out the parameters in batch from the inverter and stores them in EEPROM inside
the digital operator. When the read-out is executed, the previously stored parameters
data in the EEPROM are cleared and replaced with the newly entered parameters.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting
Name
Unit
Range
rdy: READY
rEd: READ
CPy: COPY
vFy: Verify
-
vA: Inverter capacity
display
Sno: Software number
display
Setting
Name
Unit
Range
Prohibiting
0: READ prohibited
1
parameter read
1: READ allowed
selection
Initial
Setting
rdy
Initial
Setting
0